How many digitalMLPA samples can I combine in a single run?

in Sequencing
  • digitalMLPA

You can calculate the maximum number of digitalMLPA samples that can be included in a single sequencing run using the calculator below.

Click here if the calculator does not load properly.

Background

The calculator uses the formula below with a minimum desired read depth of 500.

MRC Holland only has a limited number of barcodes available (see the product description of the probemix for details about the barcode plates that are suitable for the probemix). Depending on the machine and the Illumina reagent kit capacity, the number of samples that can be combined in a single run may be limited either by the reagent kit capacity or by the number of available barcodes.

Note
The required read depth of 400 as mentioned in the digitalMLPA General Protocol is the absolute minimum. To avoid potential warnings for median total reads and read depth during analysis with Coffalyser digitalMLPA, it is recommended to use 500 as required minimum read depth. Determining the optimal value for your system may require some optimization.

Related Pages

  • Can multiple digitalMLPA probemixes, versions or experiments be combined in a single run?

Rate the quality of this page

This page was helpful :) :( This page was not helpful
If you have any comments or suggestions on this article, please send us your feedback.

Disclaimer

The information provided in this material is correct for the majority of our products. However, for certain applications, the instructions for use may differ. In the event of conflicting information, the relevant instructions for use take precedence.


Quick Jump
  • « MRCHolland.com
  • Help Centre
  • Downloads
  • Contact Us
Top
Logo MRC-Holland
  • Products
    • Reagents
    • How to Order
    • Order Form
  • Technology
    • MLPA
    • digitalMLPA
    • Melt Assays
    • Software
  • About Us
    • Our Mission
    • Foundation
    • Careers
    • Contact
  • News & Events
    • Events
    • News Archive
  • Support
    • Help Centre
    • Downloads
    • Contact Support
    • BSI Assurance Mark - ISO 13485
  • © MRC Holland. All rights reserved.
  • Privacy Policy.
  • Website designed and developed by Schuttelaar & Partners.