Logo MRC Holland
  • Products
  • Technology
  • About Us
  • News & Events
  • Support
  • Sign in
    • Products
      • Reagents
      • How to Order
      • Order Form
    • Technology
      • MLPA
      • digitalMLPA
      • Melt Assays
      • Software
    • About Us
      • Our Mission
      • Foundation
      • Careers
      • Contact
    • News & Events
      • Events
      • News Archive
    • Support
      • Help Centre
      • Downloads
      • Contact Us
BSI Assurance Mark - ISO 13485
  • Help Centre
  • Downloads
  • Contact Us
  • Downloads Browse our downloads
  • Contact Us We are here to help
  • Support
  • Help Centre
  • MLPA & Coffalyser.Net
  • Coffalyser.Net Data Analysis Software
  • Data Analysis
  • Comparative Analysis
  • How do I match digested samples to their undigested counterparts in an MS-MLPA analysis in Coffalyser.Net?

How do I match digested samples to their undigested counterparts in an MS-MLPA analysis in Coffalyser.Net?

in Comparative Analysis
  • MS-MLPA
  • Coffalyser.Net
Note
This article is part of the Coffalyser.Net Tips & Tricks collection.

To analyse MS-MLPA data, digested samples have to be linked to their undigested counterparts. This can be done manually for each sample in the comparative analysis tab (in the digested column). This is explained in more detail in section 6b of the Coffalyser.Net Reference Manual.

Coffalyser.Net also features automatic matching of digested and undigested samples. Automatic matching only works if the sample names are similar.

  1. After the fragment analysis, navigate to the comparative analysis tab.
  2. Right-click in the window and select Digested samples (For MS-MLPA) > Match Sample Automatically.
  3. Select the samples that you want to include in the comparative analysis.
  4. Click Start Comparative Analysis and click OK to continue.

If you are having difficulty with the automatic matching algorithm, try giving your samples the same name with the exception of a short identifier that indicates whether the sample was digested (e.g. 'DIG') or undigested (e.g. 'UN').

You can see the automatic matching of digested and undigested samples in action in the short video below.

In case you're unable to view the video on YouTube you can also watch it here.

Rate the quality of this page

This page was helpful :) :( This page was not helpful
If you have any comments or suggestions on this article, please send us your feedback.

Disclaimer

The information provided in this material is correct for the majority of our products. However, for certain applications, the instructions for use may differ. In the event of conflicting information, the relevant instructions for use take precedence.


Quick Jump
  • « MRCHolland.com
  • Help Centre
  • Downloads
  • Contact Us
Top
Logo MRC-Holland
  • Products
    • Reagents
    • How to Order
    • Order Form
  • Technology
    • MLPA
    • digitalMLPA
    • Melt Assays
    • Software
  • About Us
    • Our Mission
    • Foundation
    • Careers
    • Contact
  • News & Events
    • Events
    • News Archive
  • Support
    • Help Centre
    • Downloads
    • Contact Support
    • BSI Assurance Mark - ISO 13485
  • © MRC Holland. All rights reserved.
  • Privacy Policy.
  • Website designed and developed by Schuttelaar & Partners.